Tolerances In Hydraulic and pneumatic Cylinders

TOLERANCES IN HYDRAULIC AND PNEUMATIC CYLINDERS

 

 

NOMINAL DIMENSION (mm) HOLE TOLERANCES (μm)   ROD TOLERANCES (μm)
> <= H8 H9 H10 H11 H12 e9 f7 f8 f9 h8 h9 h10 h11
  3 +14 +25 +40 +60 +100 -14 -6 -6 -6 0 0 0 0
    -0 -0 -0 -0 -0 -39 -16 -20 -31 -14 -25 -40 -60
3 6 +18 +30 +48 +75 +120 -20 -10 -10 -10 0 0 0 0
    -0 -0 -0 -0 -0 -50 -22 -28 -40 -18 -30 -48 -75
6 10 +22 +36 +58 +90 +150 -25 -13 -13 -13 0 0 0 0
    -0 -0 -0 -0 -0 -61 -28 -35 -49 -22 -36 -58 -90
10 18 +27 +43 +70 +110 +180 -32 -16 -16 -16 0 0 0 0
    -0 -0 -0 -0 -0 -75 -34 -43 -59 -27 -43 -70 -110
18 30 +33 +52 +84 +130 +210 -40 -20 -20 -20 0 0 0 0
    -0 -0 -0 -0 -0 -92 -41 -53 -72 -33 -52 -84 -130
30 50 +39 +62 +100 +160 +250 -50 -25 -25 -25 0 0 0 0
    -0 -0 -0 -0 -0 -112 -50 -64 -87 -39 -62 -100 -160
50 80 +46 +74 +120 +190 +300 -60 -30 -30 -30 0 0 0 0
    -0 -0 -0 -0 -0 -134 -60 -76 -104 -46 -74 -120 -190
80 120 +54 +87 +140 +220 +350 -72 -36 -36 -36 0 0 0 0
    -0 -0 -0 -0 -0 -159 -71 -90 -123 -54 -87 -140 -220
120 180 +63 +100 +160 +250 +400 -85 -43 -43 -43 0 0 0 0
    -0 -0 -0 -0 -0 -185 -83 -106 -143 -63 -100 -160 -250
180 250 +72 +115 +185 +290 +460 -100 -50 -50 -50 0 0 0 0
    -0 -0 -0 -0 -0 -215 -96 -122 -165 -72 -115 -185 -290
250 315 +81 +130 +210 +320 +520 -110 -56 -56 -56 0 0 0 0
    -0 -0 -0 -0 -0 -240 -108 -137 -185 -81 -130 -210 -320
315 400 +89 +140 +23 +360 +570 -125 -62 -62 -62 0 0 0 0
    -0 -0 -0 -0 -0 -265 -119 -151 -202 -89 -140 -230 -360
400 500 +97 +155 +250 +400 +630 -135 -68 -68 -68 0 0 0 0
    -0 -0 -0 -0 -0 -290 -131 -165 -223 -97 -155 -250 -400